CAE Lucina OB-GYN High Fidelity Patient Simulator, Dark or Medium Skin Tone

As low as Call For Price
Vendor direct - Longer lead times may apply
SKU
HF-12-81-3541P

Deliver an immersive prepartum and postpartum training experience with CAE Lucina, an advanced maternal simulator designed for everything from everyday care to difficult deliveries.

Lucina delivers an all-in-one simulation experience. Designed to demonstrate both gravid and non-gravid scenarios, this wireless manikin includes a fetus to teach proper prepartum, labor, delivery, and postpartum care as well as a non-gravid abdomen for clinical situations unrelated to maternity.

Integrated with maternal-fetal physiological modeling, Lucina automatically reacts to medical interventions while the baby cries upon delivery and senses the amount of force applied to its neck.

Packed with advanced features and multiple simulated clinical experiences, Lucina helps learners:

  • Evaluate anterior and posterior lung sounds
  • Witness realistic uterine contractions
  • Monitor vital signs and maternal data
  • Hear the fetal heartbeat
  • Cut and clamp umbilical cords
  • Control postpartum bleeding and uterine inversions
  • Perform CPR and analyze metrics

CAE Lucina supports pregnancy conditions such as breech delivery, shoulder dystocia, and postpartum hemorrhage. Additional equipment is available to help teach the all-fours birthing position.

Valuable Preparation for Quality Healthcare

Labor and delivery scenarios often require assistance from various healthcare providers—and with Lucina, every necessary health professional is covered, resulting in a true interprofessional education experience for learners.

General Practitioners:

  • Detect normal and abnormal maternal-fetal vitals with authentic heart, lung, and fetal sounds

Obstetricians:

  • Train to care for true-to-life pregnancy scenarios with realistic birth canal, uterine contractions, fetus rotations and post-partum options

Midwives:

  • Sharpen skills on various birthing positions and the McRoberts maneuver for shoulder dystocia

Maternal Features:

  • Airway and Breathing:
    • Realistic upper airway
    • Positive pressure ventilation
    • Bag-valve-mask ventilation
    • Advanced lungs with mechanical ventilation support, including patient-triggered modes
    • Airway management and ventilation
    • Supports endotracheal tubes, nasopharyngeal and oropharyngeal airways
    • Spontaneous breathing with chest excursion
    • Lung auscultation: anterior and posterior
  • Cardiovascular:
    • Correct hand placement detection
    • Advanced CPR analysis (compression depth and rate, chest recoil, compression fraction, ventilation volume and rate)
    • Compliant with 2020 AHA BLS guidelines and 2021 ERC guidelines
    • Pacing, cardioversion, and defibrillation
    • NIBP by auscultation and palpation
    • Heart sounds
  • Circulatory System:
    • Electrocardiogram (ECG) monitoring posts for interface with real ECG monitor
    • 12-Lead dynamic ECG display
    • Dynamic bilateral pulses: carotid, radial, brachial, and dorsalis pedis
    • Variable pulse strength
  • Fetus
    • Fetal heart sounds (five locations based on fetal presentation)
    • Articulated fetal body and neck (with lateral neck movement), shoulders, elbows, hips, and knees
    • Clinically accurate fetal size with tactile realism–50th percentile on the WHO growth chart
    • Fetal neck traction sensing
    • Palpable fontanel and sagittal suture
    • Fetal airway suctioning
    • Programmable audible cry upon delivery
    • Predicted 1-minute and 5-minute Apgar scores based on fetal blood-gas values
    • Umbilical cord that can be cut and clamped
  • Fluids
    • Postpartum bleeding tank (1.8 L)
    • Bilateral IV arms
    • Urinary catheterization
    • Epidural infusion
  • Intrapartum
    • Realistic palpable uterine contractions
    • Controllable rate and duration of contractions
    • Trendelenburg position with detection
    • Left lateral tilt with detection
    • Vertex and breech delivery
    • McRoberts maneuver with observable pelvic tilt
    • Suprapubic pressure support and detection with palpable symphysis pubis
    • Supports delivery of posterior arm during shoulder dystocia
    • Zavanelli maneuver with detection
    • C-section team training support
    • Rubin II and Woods: Screw maneuvers to resolve shoulder dystocia
    • Forceps application
    • Vacuum extraction
    • Intact/fragmented placenta with realistic color, texture, and flexibility
  • Obstetrical
    • Integrated maternal-fetal physiological modeling
    • Realistic birth canal and vulva
    • Perineum support with accurate fetal descent and rotation
    • Multiple birthing positions: lithotomy, sitting and all-fours
    • Rectal suppository administration
    • Urgent obstetrical learning module
  • Postpartum
    • Postpartum hemorrhaging, including Class III hemorrhage
    • Contracted and boggy uterus
    • Bimanual compression and uterine massage with detection and automatic response
    • Uterine blood released upon massage
    • Inverted postpartum uterus
    • Uterine reversion
    • Intrauterine balloon insertion
  • Prepartum
    • Vaginal examinations for evaluation of the cervix, fetal station, and position
    • Static cervices represent various stages of dilation from closed to 5 cm, and effacement from 0 to 90%
    • Leopold’s maneuvers
    • Epidural port with infusion and aspiration
  • Speech
    • 2-Way voice communication
    • Pre-recorded speech
    • User-recorded speech

Included Equipment:

  • Wireless and tetherless maternal manikin
  • Birthing fetus
  • Fetus to support Leopold’s maneuvers
  • (2) Abdomens (1 for delivery, 1 for prepartum and postpartum)
  • Postpartum uterus
  • Static cervices for vaginal exams
  • Additional static cervices
  • Software-compatible tablet
  • CAE Maestro operating software
  • Fully and partially inverted uterus with a Uterine Inversion SCE
  • Wireless emulated patient monitor
  • 4 Patient profiles (3 maternal, 1 non-gravid)
  • (10) Simulated clinical experiences (SCEs):
    • Normal delivery
    • Instrumental vaginal delivery
    • Fetal tachycardia (due to maternal pyrexia)
    • Breech delivery
    • Fetal central nervous system depression (due to narcotics administered to mother)
    • Shoulder dystocia
    • Major postpartum hemorrhage (due to uterine atony)
    • Maternal cardio-respiratory arrest
    • Eclampsia
    • Umbilical cord prolapse
  • (1) CAE Maestro Standalone license (manual mode)
  • (1) CAE Maestro Standalone license (modeled mode)
  • One year of CAE Premier warranty support and maintenance, Training for Life™ and option to renew
  • Electronic user guide
  • Female patient module with non-gravid abdomen and (5) SCEs:
    • Chronic heart failure exacerbation
    • Acute respiratory distress syndrome
    • Sepsis with hypotension
    • Brain attack with thrombolytic therapy
    • Motor vehicle collision with hypovolemic shock

Specifications:

  • Available in choice of Medium or Dark skin tones
  • Manikin:
    • 69" H × 22" W × 15" D
    • 111 lb.
  • Fetus:
    • 19" H × 6" W × 4.5" D
    • 5 lb.
  • Electrical:
    • Input: 100-240V, 50/60 Hz, 2.3 A
    • Internal batteries: 14.4V, lithium-ion, rechargeable
    • Maternal manikin battery life: 4 hours
    • Fetus battery life: 7 hours
More Information
Part Number HF-12-81-3541-DARK
Country of Origin US
UNSPSC Category 42301503
Harmonization Code 9023.00.00.00
Mfg# FLEX-MFS-MAESTRO-DARK
Old Item HF-11-81-3541-DARK
Warranty 1 Year Warranty
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account